Original abstract
The paper discusses some practical problems occurring at ISO 10816-1 application in technical practice. Technical diagnosticians find out frequently that the zone boundaries proposed by the standard are not sensitive adequately to the changes in vibrations during operation resulting from a change of technical condition of the machine. The principle of statistical determination of individual operational limits from the measured overall level of RMS vibration velocity (overall level) with utilization of statistical regulation of individual values is also described in the paper. The alarm limit for the overall level (boundary between the B and C zones) in the range 10 Hz to 1,000 Hz is specified in the paper on the basis of measuring of vibrations on the electric motor of Bosch Rexroth hydraulic unit.
Keywords in English
operational limits; vibration diagnostics; zones boundary
Released
2015-09-21
Publisher
Springer International Publishing AG Switzerland
Location
Spolková republika Německo
ISSN
2194-5357
Journal
Advances in Intelligent Systems and Computing
Volume
1
Number
393
Pages from–to
13–18
Pages count
6
BIBTEX
@article{BUT118087,
author="Róbert {Jankových} and Tomáš {Budík} and Miloš {Hammer}",
title="Operational Limits in Vibration Diagnostics",
journal="Advances in Intelligent Systems and Computing",
year="2015",
volume="1",
number="393",
pages="13--18",
doi="10.1007/978-3-319-23923-1",
issn="2194-5357",
url="http://www.springer.com/series/11156"
}