Calculation of Cogeneration Potential of Total Site Utility Systems with Commercial Simulator

Ren, X.Y. Jia, X. Varbanov, P.S. Klemeš, .J.J. Liu Z.Y.

English title

Calculation of Cogeneration Potential of Total Site Utility Systems with Commercial Simulator

Type

conference paper

Language

en

Original abstract

Cogeneration potential of utility systems is one of the important indicators for the design of Total Site utility systems. In this paper, a new method is proposed to calculate cogeneration potential of Total Site utility systems. The temperatures of steam mains are calculated with Aspen Plus simulator first. Steam flow rates are calculated based on temperatures of steam mains and head loads of process, then. Based on the temperatures and steam flow rates obtained, shaft powers generated by the steam turbines in expansion zones can be obtained with the built-in block COMPR in Aspen Plus simulator. Compared to the existing methods, the method proposed needs not complex calculation procedure. For the illustrated case studies, the results obtained by this method are comparable to that obtained in the literature. It is shown that the calculation procedure proposed in this paper is simple, and the results are accurate.

English abstract

Cogeneration potential of utility systems is one of the important indicators for the design of Total Site utility systems. In this paper, a new method is proposed to calculate cogeneration potential of Total Site utility systems. The temperatures of steam mains are calculated with Aspen Plus simulator first. Steam flow rates are calculated based on temperatures of steam mains and head loads of process, then. Based on the temperatures and steam flow rates obtained, shaft powers generated by the steam turbines in expansion zones can be obtained with the built-in block COMPR in Aspen Plus simulator. Compared to the existing methods, the method proposed needs not complex calculation procedure. For the illustrated case studies, the results obtained by this method are comparable to that obtained in the literature. It is shown that the calculation procedure proposed in this paper is simple, and the results are accurate.

Keywords in English

Cogeneration plants; Simulators; Steam; Steam turbines; Aspen Plus Simulators; Calculation procedure; Case-studies; Cogeneration potential; Commercial simulators; Site utility systems; Steam flow rate; Utility systems; Computer software;

Released

01.10.2017

Publisher

Italian Association of Chemical Engineering - AIDIC

ISBN

978-88-95608-51-8

ISSN

2283-9216

Book

Chemical Engineering Transactions

Number

61

Pages from–to

1231–1236

Pages count

6

BIBTEX


@inproceedings{BUT146097,
  author="Xuexiu {JIA} and Petar Sabev {Varbanov} and Jiří {Klemeš},
  title="Calculation of Cogeneration Potential of Total Site Utility Systems with Commercial Simulator",
  booktitle="Chemical Engineering Transactions  ",
  year="2017",
  number="61",
  month="October",
  pages="1231--1236",
  publisher="Italian Association of Chemical Engineering - AIDIC",
  isbn="978-88-95608-51-8",
  issn="2283-9216"
}