Publication detail
Heat Exchanger Leakage Problem Location
HEJČÍK, J. JÍCHA, M.
English title
Heat Exchanger Leakage Problem Location
Type
Paper in proceedings (conference paper)
Language
en
Original abstract
This paper describes a procedure used to identify the leakage location inside the prime surface gas turbine rekuperators. For this purpose, an analytical model of the leaky gas turbine recuperator was created to assess its performance. The results obtained are compared with the experimental data which were acquired during the recuperator thermal performance analysis. The differences between these two data sets are used to indicate possible leakage areas.
Keywords in English
Heat exchanger, leakage, thermal performance
Released
2012-04-16
Publisher
EDP Sciences
ISBN
978-80-7372-670-6
ISSN
2100-014X
Book
EPJ Web of Conferences
Journal
EPJ Web of Conferences
Volume
25
Number
1
Pages from–to
188–191
Pages count
4
BIBTEX
@inproceedings{BUT36937,
author="Jiří {Hejčík} and Miroslav {Jícha}",
title="Heat Exchanger Leakage Problem Location",
booktitle="EPJ Web of Conferences",
year="2012",
journal="EPJ Web of Conferences",
volume="25",
number="1",
pages="188--191",
publisher="EDP Sciences",
doi="10.1051/epjconf/20122502006",
isbn="978-80-7372-670-6",
issn="2100-014X",
url="https://www.epj-conferences.org/articles/epjconf/abs/2012/07/epjconf_EFM2011_02006/epjconf_EFM2011_02006.html"
}