Precise Conductivity Measurements with Thick-Film IDEs

HUBÁLEK, J. KREJČÍ, J.

Czech title

Precise Conductivity Measurements with Thick-Film IDEs

English title

Precise Conductivity Measurements with Thick-Film IDEs

Type

conference paper

Language

en

Original abstract

Thick-film Pt interdigitated electrodes (IDEs) are used as miniature and cheap chemical sensor for widespread use as conductivity-based transducer. The planar sensor has been characterised by a precise impedance analyser over a wide range of frequencies and conductivities. The frequency characteristics have been studied to describe the electrode behaviour, and for comparison with theory. We found relations between conductivity and frequency. The ridge frequency was detected as suitable measuring frequency to improve accuracy. Extracted relations can be used as correction characteristics. The correction factor was determined for wide range of conductivity to take precise measurements without cell replacement.

Czech abstract

Thick-film Pt interdigitated electrodes (IDEs) are used as miniature and cheap chemical sensor for widespread use as conductivity-based transducer. The planar sensor has been characterised by a precise impedance analyser over a wide range of frequencies and conductivities. The frequency characteristics have been studied to describe the electrode behaviour, and for comparison with theory. We found relations between conductivity and frequency. The ridge frequency was detected as suitable measuring frequency to improve accuracy. Extracted relations can be used as correction characteristics. The correction factor was determined for wide range of conductivity to take precise measurements without cell replacement.

English abstract

Thick-film Pt interdigitated electrodes (IDEs) are used as miniature and cheap chemical sensor for widespread use as conductivity-based transducer. The planar sensor has been characterised by a precise impedance analyser over a wide range of frequencies and conductivities. The frequency characteristics have been studied to describe the electrode behaviour, and for comparison with theory. We found relations between conductivity and frequency. The ridge frequency was detected as suitable measuring frequency to improve accuracy. Extracted relations can be used as correction characteristics. The correction factor was determined for wide range of conductivity to take precise measurements without cell replacement.

Keywords in Czech

thick-film; interdigitated electrodes; conductivity measurements; correction factor; ridge frequency

Keywords in English

thick-film; interdigitated electrodes; conductivity measurements; correction factor; ridge frequency

RIV year

2002

Released

09.09.2002

Publisher

Ing. Zdeněk Novotný, CSc., Brno, Ondráčkova 105

Location

Brno

ISBN

80-214-2180-0

Book

EDS 2002 Electronic Devices and Systems Conference

Pages count

5

BIBTEX


@inproceedings{BUT4947,
  author="Jaromír {Hubálek} and Jan {Krejčí},
  title="Precise Conductivity Measurements with Thick-Film IDEs",
  booktitle="EDS 2002 Electronic Devices and Systems Conference",
  year="2002",
  month="September",
  publisher="Ing. Zdeněk Novotný, CSc., Brno, Ondráčkova 105",
  address="Brno",
  isbn="80-214-2180-0"
}