Publication detail
Evaluation of dynamic forces established during the Taylor Anvil Test
ŠLAIS, M. KNEBL, M. FOREJT, M.
English title
Evaluation of dynamic forces established during the Taylor Anvil Test
Type
Peer-reviewed article not indexed in WoS or Scopus
Language
en
Original abstract
This paper deals with innovation possibilities in the measurement of dynamic forces that act on the specimen during the Taylor anvil test. The goal of this work is to decrease the influence of unwanted noises in the pulse record. The Quartz Force link piezoelectric sensor by Kistler was used to compare the waveform of shock loading with signals recorded by foil resistance strain gauges by Hottinger. The impact loading was produced by impact of specimen on the measuring rod.
Keywords in English
Taylor Anvil Test, high strain rate, impact loading, strain gauges ,
Released
2010-12-17
Publisher
MM publishing, s.r.o.
Location
Praha
ISSN
1803-1269
Journal
MM Science Journal
Volume
2010
Number
4
Pages from–to
214–217
Pages count
3
BIBTEX
@article{BUT50285,
author="Miroslav {Šlais} and Martin {Knebl} and Milan {Forejt}",
title="Evaluation of dynamic forces established during the Taylor Anvil Test",
journal="MM Science Journal",
year="2010",
volume="2010",
number="4",
pages="214--217",
issn="1803-1269"
}