Original abstract
The article describes results of durability test of a magnetorheological fluid (MRF), which was carried out in rheometer of own design. The rheometer design enables to measure the rheological properties of MR fluid and to expose it to a long-term loading simultaneously, without any manipulation of the measured sample. During the durability test a change of the two most important parameters of Bingham model describing the behavior of MR fluids can be followed – dynamic viscosity and yield stress. In this paper the yield stress and viscosity were evaluated depending on temperature in OFF-state. The results show a significant change of yield strength during durability test depending on temperature of loading. Dependence of yield stress on temperature was proved. The viscosity decreased by 36% from its initial value after the dissipation of 9-20kJ.cm-3 from total 1.2 MJ.cm-3 and then has remained the same until the end of durability test. Viscosity was evaluated depending on temperature.
Keywords in English
MR fluid, MR damper, magnetorheological, Bingham model, viscosity, yield stress, durability test, high shear rates
Released
2012-08-27
Publisher
IOP Publishing
ISSN
1742-6588
Journal
Journal of Physics: Conference Series
Volume
412
Number
1
Pages from–to
1–8
Pages count
8
BIBTEX
@article{BUT93430,
author="Jakub {Roupec} and Ivan {Mazůrek} and Zbyněk {Strecker} and Milan {Klapka}",
title="The Behavior of the MR Fluid During Durability Test",
journal="Journal of Physics: Conference Series",
year="2012",
volume="412",
number="1",
pages="1--8",
doi="10.1088/1742-6596/412/1/012024",
issn="1742-6588",
url="http://iopscience.iop.org/article/10.1088/1742-6596/412/1/012024"
}