Publication detail
Experimental air ground heat exchanger and its construction
JAROŠ, M. KOLBÁBEK, A. MUSIL, Z.
English title
Experimental air ground heat exchanger and its construction
Type
Paper in proceedings (conference paper)
Language
en
Original abstract
The article reports on a newly realized experimental ground heat exchanger (GHE), which has been built up as an accessory of an experimental low-energy dwelling of Faculty of Mechanical Engineering of Brno University of Technology (FME BUT), and analyzes some aspects of its project, especially a choice of proper tubing. Based on a simplified computational model, an impact of four most employed types of tubing on a performance and an effectiveness of the GHE has been judged and benefits of particular types of tubing were compared with their investment costs. Finally, using of KG-Systém (PVC) SN4 was evaluated as the best variant.
Keywords in English
ground heat exchanger, ventilation, energy savings, anti-frost protection
Released
2013-06-26
Publisher
ČVUT
Location
Praha
ISBN
978-80-247-5015-6
Book
CESB
Pages from–to
361–364
Pages count
992
BIBTEX
@inproceedings{BUT95301,
author="Michal {Jaroš} and Antonín {Kolbábek} and Zdeněk {Musil}",
title="Experimental air ground heat exchanger and its construction",
booktitle="CESB",
year="2013",
pages="361--364",
publisher="ČVUT",
address="Praha",
isbn="978-80-247-5015-6"
}