Originální abstrakt
There are presented characteristics of the pipe junction for the case of the flow division in this paper. The pipe junction consists of one straight pipe, with the diameter 50 mm and one adjacent pipe with diameter 32 mm. The characteristics have been measured for five different angles of the adjacent pipe.
Klíčová slova anglicky
Fluid flow in pipe junction, flow difision, characteristic curves for pipe junction