Originální abstrakt
A new and up to date incineration plant for municipal solid waste treatment (MSWI) with capacity of 96 000 t/yr has been extended by a baghouse filter equipped by high durability filter fabric with ePTFE membrane and containing catalyst for destruction of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F). This step was necessary because of more and more sweeping environmental regulations. For destruction of dioxins has been applied the technology REMEDIA D/F. The concept of the employed technology consists in that the gaseous combustion products containing dioxins pass through the membrane into a catalytic felt substrate where the dioxins are destroyed by catalytic reaction. This technology enables both simultaneous removal of solid particles and destruction of polychlorinated dibenzo-p-dioxins and dibenzofurans well below the allowable limit given by environmental regulation.
Klíčová slova anglicky
Waste Treatment, Gas Cleaning, Emissions, Dioxins, Catalytic Filter, Fabric Filter
Vydáno
2005-08-15
Místo
Wiesbaden
Kniha
Filtech 2005
Strany od–do
400–408
Počet stran
8
BIBTEX
@inproceedings{BUT17997,
author="Ladislav {Bébar} and Gernot {Pranghofer} and Radim {Puchýř} and Tomáš {Pařízek} and Pavel {Bernát} and Petr {Stehlík}",
title="Optimum involvement of dioxin catalytic filter in MSW incinerator",
booktitle="Filtech 2005",
year="2005",
pages="400--408",
address="Wiesbaden"
}