Small fatigue crack growth in aluminium alloy EN AW-6082/T6
LIŠKUTÍN, P. JÍŠA, D. KRUML, T. POLÁK, J.
Anglický název
Small fatigue crack growth in aluminium alloy EN AW-6082/T6
Typ
Článek recenzovaný mimo WoS a Scopus
Jazyk
en
Originální abstrakt
The kinetics of small fatigue crack growth at room temperature was measured by a direct observation of the shallow notch on a cylindrical specimen. The growth of the crack was measured within the range of half surface crack length from ~10 micrometers up to ~2 mm. A linear dependence between the crack growth rate and the crack length, observed in case of steels, was confirmed to be valid in the aluminium 6082/T6 alloy, too. The crack growth coefficient kg increases with plastic strain amplitude; this dependence is well described by a power law. The fatigue life prediction based on the crack growth measurements is compared with the Manson-Coffin law.
Klíčová slova anglicky
aluminium alloy, small fatigue crack, crack crowth rate, crack nucleation
Vydáno
2010-08-01
Nakladatel
Elsevier
Místo
London
ISSN
0142-1123
Časopis
International Journal of Fatigue
Ročník
32
Číslo
12
Strany od–do
1913–1920
Počet stran
8
BIBTEX
@article{BUT49753,
author="Petr {Liškutín} and David {Jíša} and Tomáš {Kruml} and Jaroslav {Polák}",
title="Small fatigue crack growth in aluminium alloy EN AW-6082/T6",
journal="International Journal of Fatigue",
year="2010",
volume="32",
number="12",
pages="1913--1920",
issn="0142-1123"
}