Detail publikace
Research on Cooling Efficiences of Water, Emulsions and Oil
HORÁK, A. RAUDENSKÝ, M. POHANKA, M. BELLEROVÁ, H. REICHARDT, T.
Anglický název
Research on Cooling Efficiences of Water, Emulsions and Oil
Typ
Článek recenzovaný mimo WoS a Scopus
Jazyk
en
Originální abstrakt
Pure water is considered a s a coolant in main technologies connected with steel processing. Some technologies use addtives for lubrication and anti-corrosion reasons. The paper deals with decreasing of cooling intensity when another coolants are used instead of pure water. Program of experiments provided extensive quantitative information useful for wide range if industrial spray cooling.
Klíčová slova anglicky
spray cooling, water cooling, emulsion cooling, oil cooling experimental
Vydáno
2010-07-31
ISSN
2076-0507
Časopis
Metallurfical and Mining Industry
Ročník
2
Číslo
4
Strany od–do
271–278
Počet stran
8
BIBTEX
@article{BUT50077,
author="Aleš {Horák} and Miroslav {Raudenský} and Michal {Pohanka} and Hana {Bellerová} and Tilo {Reichardt}",
title="Research on Cooling Efficiences of Water, Emulsions and Oil",
journal="Metallurfical and Mining Industry",
year="2010",
volume="2",
number="4",
pages="271--278",
issn="2076-0507"
}