Detail publikace
The Fluid Flow in the T-Junction. The Comparison of the Numerical Modelling and PIV Measurement.
ŠTIGLER, J. KLAS, R. KOTEK, M. KOPECKÝ, V.
Anglický název
The Fluid Flow in the T-Junction. The Comparison of the Numerical Modelling and PIV Measurement.
Typ
Kapitola, resp. kapitoly v odborné knize
Jazyk
en
Originální abstrakt
There is presented the fluid flow in the T-junction with the 90 degree angle of the adjacent branch and with the 50mm diameter of each branch, in this chapter. The flow is organized as a combining flow. It means that there are two inlet branches and only one outlet branch. There are two possible kinds of the flow combinations for this T-junction. The CFD calculations and the PIV measurements were done for both flow combinations. Its comparison is presented in this paper.
Klíčová slova anglicky
Combining T-Junction, PIV measurements, CFD calculations
Vydáno
2011-09-05
Místo
Sumy, Ukraine
ISBN
978-966-657-384-4
Kniha
Těorija i praktika nacoco – i kompressorostrojenija
Strany od–do
240–247
Počet stran
8
BIBTEX
@inbook{BUT88494,
author="ŠTIGLER, J. and KLAS, R. and KOTEK, M. and KOPECKÝ, V.",
title="The Fluid Flow in the T-Junction. The Comparison of the Numerical Modelling and PIV Measurement.",
booktitle="Těorija i praktika nacoco - i kompressorostrojenija",
year="2011",
address="Sumy, Ukraine",
series="tech. nauka - monografie",
edition="1",
pages="240--247",
isbn="978-966-657-384-4"
}